Fire Pump Controller

$ 1900.8

Availability: 98 in stock
  • All returns accepted: ReturnsNotAccepted
  • MPN: FTA1350-AM40B
  • Condition: Some cosmetic scratches and pre-drilled holes. Has never been started up/used. Original documentation inside.
  • Type: Fire Pump Controller
  • Model: FTA1350-AM40B
  • Brand: Firetrol

    Description

    NUMBER: FTA1350-AM40B
    SERIAL NUMBER: 1742891-01RE
    ENCLOSURE TYPE: 2
    HP: 40
    VOLTS: 440 – 480
    PHASE: 3
    HERTZ: 60
    MAX SYS. PRESSURE
    PSI: 300
    BARS: 21
    SUITABLE FOR USE ON CIRCUIT CAPABLE OF DELIVERING NOT MORE THAN:
    100,000 NORMAL
    Description
    —Firetrol
    ®
    FTA1350 Wye-Delta, Closed Transition Starting Fire Pump Controllers
    are used with delta-wound squirrel cage motors. FTA1350 con­trollers are of the closed circuit transition type in which the motor circuit remains closed during the transition from start to run. The controller monitors, displays and records fire pump system information. Actuating the controller by the pressure switch, START pushbutton or deluge valve contact closes the start contactor connecting the motor to the line in the wye connection. The motor will draw approximately 33% of its normal inrush current and develop approximately 33% of its normal starting torque. After a time delay, the motor is automatically reconnected in delta, ap­plying full voltage to the motor windings. During this transition, a resistor is connected to each phase, mini­mizing line disturbances and voltage drop during start­ing. These controllers are recommended especially for use with generator sets.
    Approvals
    —Firetrol fire pump controllers are listed by Underwriters' Laboratories, Inc., in accordance with UL218,
    Standard for Fire Pump Controllers
    , CSA,
    Standard for Industrial Control Equipment
    , and ap­proved by Factory Mutual. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest editions of NFPA 20,
    Installation of Centrifugal Fire Pumps
    , and NFPA 70,
    National Electrical Code
    .
    Standard Features
    —The following are included as standard with each controller:

    Voltage surge protector

    Main Disconnect Switch sized for connected mo­tor horsepower and voltage

    Fire pump Circuit Breaker

    Motor contactor

    Emergency Manual Run Mechanism to mechani­cally close motor contactor contacts in an emer­gency condition

    Built-in Start and Stop push-buttons to bypass automatic start circuits

    Door mounted display/interface panel featuring a 40 Character Vacuum Fluorescent Display, Mem­brane Type User Control Push-buttons and easy to read LED Indicators

    Single handle Isolating Disconnect Switch/Circuit Breaker mechanism

    POWER ON
    LED

    PUMP RUN
    LED

    PHASE FAILURE
    LED

    PHASE REVERSAL
    LED

    LOW PRESSURE
    LED

    DELUGE OPEN
    LED

    INTERLOCK ON
    LED

    TRANSFER SWITCH NORMAL
    LED (If unit or­dered with Automatic Power Transfer Switch)

    TRANSFER SWITCH EMERGENCY
    LED (If unit ordered with Automatic Power Transfer Switch)

    EMERGENCY ISOLATING SWITCH OFF
    LED (If unit ordered with Automatic Power Transfer Switch)

    Minimum Run Timer / Off Delay Timer

    Daylight Savings Time option

    Weekly Test Timer

    Motor Acceleration Timer

    Elapsed Time Meter

    Digital Pressure Display

    1.44M Floppy Disk Drive

    Data Log

    Event Log (3000 Events)

    True RMS Metering with simultaneous 3 phase display of amps and volts

    Disk Error message

    Disk Near Full message

    Pressure Error message

    Motor Over 320% message

    Local Start message

    Remote Start message

    Emergency Start message

    Fail To Start message

    Undervoltage message

    Overvoltage message

    Low Suction Pressure message

    High Speed Open Serial Communications Port

    NEMAType 2 enclosure
    SPECIAL ENCLOSURES
    -T NEMAType 3R (IEC IP14) -E NEMAType 4 (IEC IP56) -F NEMAType 4X (IEC IP56)
    FTA1000, 1250, 1300 FTA1350, 1500, 1800, 1900 -G NEMAType 12 (IEC IP52)
    CIRCUIT BREAKER OPTION
    -N Intermediate withstand rating150,000 Amps RMS Sym. -P High withstand rating
    200,000 Amps RMS Sym
    Note:
    Intermediate and High withstand ratings may not beavailable for all horsepowers and voltages. Consult factory for availability.
    ANTI-CONDENSATION SPACE HEATERS
    -H 120 Volt Space Heater -J 120 Volt Space Heater WithThermostat -K 120 Volt Space Heater With
    Humidistat -L 240 Volt Space Heater -M 240 Volt Space Heater With
    Thermostat -N 240 Volt Space Heater WithHumidistat
    PRESSURE TRANSDUCERS
    -B 0-600 psi (0-42.25 bar)Pressure Transducer for Fresh Water Service
    -C 0-300 psi (0-21.1 bar)Pressure Transducer for Sea Water, Foam or CopperCorrosive Service
    -D 0-600 psi (0-42.25 bar)Pressure Transducer for Sea Water, Foam or CopperCorrosive Service
    AUTOMATIC POWER TRANSFER SWITCHES
    (Refer to publication SD900-21)FTA900 - generator set emergency supplyFTA901 - bypass isolation switch for generator setemergency supplyFTA950 - second utility emergency supplyFTA951 - bypass isolation switch for second utilityemergency supply
    ALARMS
    -AC Extra contacts (normally open &normally closed) for remoteindication, pump operating
    -AF Audible and Visible low pump
    room temperature alarm -AG Built-in reservoir low alarm -AH Audible low suction pressure
    alarm -AM Contacts for remote indication,pump fail to start-AV Contacts for remote indication,low pump room temperature-AW Contacts for remote indication,reservoir low -AY Contacts for remote indication,low suction pressure
    -AZ Low pump room temperatureswitch, mounted and wired-BW Extra contacts for remote indication, phase failure/phase reversal-BY Contacts for remote indication, pump overload-COM Visible low suction pressure alarmwith manual reset push-button
    -CTS Built in Low Suction Pressure Alarm Panel (Includes selectable auto/manualreset, audible, visible and remote alarms and mounted and wired pressure switch)
    -EG Visible relief valve discharge alarm-EH Contacts for remote indication,
    relief valve discharge-EJ Built-in flow meter on alarm -EK Contacts for remote indication,
    flow meter on
    -P Built-in alarm system (Includesvisible supervisory voltage normalindication and audible pumpoperating, phase failure and phasereversal indication)
    -PB Built-in low system pressurevisible alarm with manual reset -PE Contacts for remote indication,low system pressure
    -PT Built-in alarm system, 220 VACsupervisory power (Includesvisible supervisory voltage normalindication and audible pumpoperating, phase failure and phasereversal indication)
    -HV Audible alarm device -LVA Visible pump on demand alarm-LW Audible and visible pump on
    demand alarm (requires (-HV))
    -LY Contacts for remote indication, pump on demand (requires (-LVA) or (-LW))
    MISCELLANEOUS
    -DZ Test push-button with solenoid valve* -ED Load shed circuits -EL Series pumping, high zone
    controller -EM Series pumping, mid zonecontroller(s)-EN Series pumping, low zonecontroller -PY Motor space heater output
    contacts -S Tropicalization-ZPA Customized, annual service display
    message (when factoryprogrammed or programmedby Firetrol representativeduring start-up)
    -ZPB High Quality Impact Printer with paper take-upmechanism
    Export packaging FTA1000, 1250, 1300 FTA1350, 1500, 1800, 1900