Fire Pump Controller
$ 1900.8
- Description
- Size Guide
Description
NUMBER: FTA1350-AM40BSERIAL NUMBER: 1742891-01RE
ENCLOSURE TYPE: 2
HP: 40
VOLTS: 440 – 480
PHASE: 3
HERTZ: 60
MAX SYS. PRESSURE
PSI: 300
BARS: 21
SUITABLE FOR USE ON CIRCUIT CAPABLE OF DELIVERING NOT MORE THAN:
100,000 NORMAL
Description
—Firetrol
®
FTA1350 Wye-Delta, Closed Transition Starting Fire Pump Controllers
are used with delta-wound squirrel cage motors. FTA1350 controllers are of the closed circuit transition type in which the motor circuit remains closed during the transition from start to run. The controller monitors, displays and records fire pump system information. Actuating the controller by the pressure switch, START pushbutton or deluge valve contact closes the start contactor connecting the motor to the line in the wye connection. The motor will draw approximately 33% of its normal inrush current and develop approximately 33% of its normal starting torque. After a time delay, the motor is automatically reconnected in delta, applying full voltage to the motor windings. During this transition, a resistor is connected to each phase, minimizing line disturbances and voltage drop during starting. These controllers are recommended especially for use with generator sets.
Approvals
—Firetrol fire pump controllers are listed by Underwriters' Laboratories, Inc., in accordance with UL218,
Standard for Fire Pump Controllers
, CSA,
Standard for Industrial Control Equipment
, and approved by Factory Mutual. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest editions of NFPA 20,
Installation of Centrifugal Fire Pumps
, and NFPA 70,
National Electrical Code
.
Standard Features
—The following are included as standard with each controller:
•
Voltage surge protector
•
Main Disconnect Switch sized for connected motor horsepower and voltage
•
Fire pump Circuit Breaker
•
Motor contactor
•
Emergency Manual Run Mechanism to mechanically close motor contactor contacts in an emergency condition
•
Built-in Start and Stop push-buttons to bypass automatic start circuits
•
Door mounted display/interface panel featuring a 40 Character Vacuum Fluorescent Display, Membrane Type User Control Push-buttons and easy to read LED Indicators
•
Single handle Isolating Disconnect Switch/Circuit Breaker mechanism
•
POWER ON
LED
•
PUMP RUN
LED
•
PHASE FAILURE
LED
•
PHASE REVERSAL
LED
•
LOW PRESSURE
LED
•
DELUGE OPEN
LED
•
INTERLOCK ON
LED
•
TRANSFER SWITCH NORMAL
LED (If unit ordered with Automatic Power Transfer Switch)
•
TRANSFER SWITCH EMERGENCY
LED (If unit ordered with Automatic Power Transfer Switch)
•
EMERGENCY ISOLATING SWITCH OFF
LED (If unit ordered with Automatic Power Transfer Switch)
•
Minimum Run Timer / Off Delay Timer
•
Daylight Savings Time option
•
Weekly Test Timer
•
Motor Acceleration Timer
•
Elapsed Time Meter
•
Digital Pressure Display
•
1.44M Floppy Disk Drive
•
Data Log
•
Event Log (3000 Events)
•
True RMS Metering with simultaneous 3 phase display of amps and volts
•
Disk Error message
•
Disk Near Full message
•
Pressure Error message
•
Motor Over 320% message
•
Local Start message
•
Remote Start message
•
Emergency Start message
•
Fail To Start message
•
Undervoltage message
•
Overvoltage message
•
Low Suction Pressure message
•
High Speed Open Serial Communications Port
•
NEMAType 2 enclosure
SPECIAL ENCLOSURES
-T NEMAType 3R (IEC IP14) -E NEMAType 4 (IEC IP56) -F NEMAType 4X (IEC IP56)
FTA1000, 1250, 1300 FTA1350, 1500, 1800, 1900 -G NEMAType 12 (IEC IP52)
CIRCUIT BREAKER OPTION
-N Intermediate withstand rating150,000 Amps RMS Sym. -P High withstand rating
200,000 Amps RMS Sym
Note:
Intermediate and High withstand ratings may not beavailable for all horsepowers and voltages. Consult factory for availability.
ANTI-CONDENSATION SPACE HEATERS
-H 120 Volt Space Heater -J 120 Volt Space Heater WithThermostat -K 120 Volt Space Heater With
Humidistat -L 240 Volt Space Heater -M 240 Volt Space Heater With
Thermostat -N 240 Volt Space Heater WithHumidistat
PRESSURE TRANSDUCERS
-B 0-600 psi (0-42.25 bar)Pressure Transducer for Fresh Water Service
-C 0-300 psi (0-21.1 bar)Pressure Transducer for Sea Water, Foam or CopperCorrosive Service
-D 0-600 psi (0-42.25 bar)Pressure Transducer for Sea Water, Foam or CopperCorrosive Service
AUTOMATIC POWER TRANSFER SWITCHES
(Refer to publication SD900-21)FTA900 - generator set emergency supplyFTA901 - bypass isolation switch for generator setemergency supplyFTA950 - second utility emergency supplyFTA951 - bypass isolation switch for second utilityemergency supply
ALARMS
-AC Extra contacts (normally open &normally closed) for remoteindication, pump operating
-AF Audible and Visible low pump
room temperature alarm -AG Built-in reservoir low alarm -AH Audible low suction pressure
alarm -AM Contacts for remote indication,pump fail to start-AV Contacts for remote indication,low pump room temperature-AW Contacts for remote indication,reservoir low -AY Contacts for remote indication,low suction pressure
-AZ Low pump room temperatureswitch, mounted and wired-BW Extra contacts for remote indication, phase failure/phase reversal-BY Contacts for remote indication, pump overload-COM Visible low suction pressure alarmwith manual reset push-button
-CTS Built in Low Suction Pressure Alarm Panel (Includes selectable auto/manualreset, audible, visible and remote alarms and mounted and wired pressure switch)
-EG Visible relief valve discharge alarm-EH Contacts for remote indication,
relief valve discharge-EJ Built-in flow meter on alarm -EK Contacts for remote indication,
flow meter on
-P Built-in alarm system (Includesvisible supervisory voltage normalindication and audible pumpoperating, phase failure and phasereversal indication)
-PB Built-in low system pressurevisible alarm with manual reset -PE Contacts for remote indication,low system pressure
-PT Built-in alarm system, 220 VACsupervisory power (Includesvisible supervisory voltage normalindication and audible pumpoperating, phase failure and phasereversal indication)
-HV Audible alarm device -LVA Visible pump on demand alarm-LW Audible and visible pump on
demand alarm (requires (-HV))
-LY Contacts for remote indication, pump on demand (requires (-LVA) or (-LW))
MISCELLANEOUS
-DZ Test push-button with solenoid valve* -ED Load shed circuits -EL Series pumping, high zone
controller -EM Series pumping, mid zonecontroller(s)-EN Series pumping, low zonecontroller -PY Motor space heater output
contacts -S Tropicalization-ZPA Customized, annual service display
message (when factoryprogrammed or programmedby Firetrol representativeduring start-up)
-ZPB High Quality Impact Printer with paper take-upmechanism
Export packaging FTA1000, 1250, 1300 FTA1350, 1500, 1800, 1900